Hip replacement is quickly going digital. Surgeons now study a patient’s bones on CT scans, map out the operation on a computer and rely on robots and navigation systems to check positions and changes as the surgery unfolds. All of this progress serves one purpose: rebuilding each patient’s individual joint with greater precision.
Measuring a target accurately, however, is not the same as reaching it. A surgeon may know exactly how long the leg should be and how far the joint should sit sideways, yet still struggle to carry out the plan if the implant on hand cannot deliver that particular combination. That is why, as digital surgery moves forward, implant design and the range of available products also deserve scrutiny.
Three things hip surgery has to restore: leg length, offset and stability
In hip replacement, the essential targets are leg length, offset and stability. Think of leg length as the vertical measurement and offset as the horizontal one. Femoral offset is the distance between the center of the femoral head and the axis of the femoral shaft, and it shapes the lever the surrounding muscles use to generate force. Even with the length correct, the wrong offset can reduce muscle efficiency and undermine joint stability.
The part of the implant that is inserted into the thighbone is known as the stem. It has to be anchored firmly in the bone while also producing the length and offset the patient requires. In other words, picking a size that suits the bone and recreating a joint structure that suits the patient are problems that must be solved at the same time.
The stem that suits the bone may not give the offset the patient needs
Many cementless stems hold in place by being wedged snugly into the cavity inside the bone, a technique called press-fit fixation. As a result, the width and contour of the medullary canal influence both the size of the stem body and where it ends up sitting. The details depend on the product, but length and offset frequently change together as the stem body gets bigger.
The trouble is that canal width and required offset do not always rise and fall together. One patient may have a narrow canal yet need a large offset, while another has a wide canal but needs only a small one. A small stem might sit well in the bone but leave the offset too short, and a larger stem might secure fixation but push the offset beyond what is needed.
Switching to a different head length is not a cure-all either. Since the head sits on the angled neck of the stem, a longer head adds both length and offset. Trying to recover horizontal distance can end up making the leg longer too. Choosing a size that fits the bone, then, does not by itself prove that length and offset are right as well.
A design that separates the choice of stem body size from the choice of offset
This is where the product lineup of the Exeter Stem becomes relevant. Exeter is best known as a cemented stem, but it has another notable feature: each offset comes with several body sizes. Within a 44 mm offset, for example, surgeons can pick from different body sizes. Not every offset is available in every size, yet the lineup makes it possible to treat body size and offset as two independent decisions.
Leg length can also be fine-tuned by changing how deep the stem is seated, as long as the cement mantle stays thick enough and alignment is maintained. After joint movement and stability are tested with trial components, there is still scope to adjust anteversion, the angle at which the stem neck points forward, before the stem is permanently fixed. These characteristics are best understood not merely as a matter of fixation technique but in terms of how the joint is rebuilt.
Broadening the options is a shared job for surgeons and manufacturers
Cementless stems that alter offset while keeping length the same are already available. The real question is whether such options cover the differences between individual patients well enough. Extending the range so that a smaller body could come with a larger offset, and a larger body with a smaller offset, could benefit patients who have been hard to treat with current sizes. Still, cementless stems are limited by the position they must reach to achieve stable fixation, so simply adding more offset choices will not resolve every leg length issue.
Any expansion of options must be backed by testing of each combination’s strength, initial fixation and long-term safety. The need for such testing, however, is not grounds for halting development; it is part of the work that development has to accomplish. Surgeons should also measure and document which patients’ restoration targets were difficult to reach with current products and share that information with manufacturers. Manufacturers, for their part, should study these needs and answer them with designs that cover a broader range of patient differences.
Questions and answers
If surgery is planned with digital tools, will a hip replacement automatically be more accurate?
No. CT, robots and navigation may pinpoint the target, but if the implant cannot supply the needed mix of leg length and offset, the plan will be hard to realize. Implant design and the available product range have to be taken into account too.
How can the offset be off even though the stem fits the bone?
With many cementless stems, a bigger stem body brings changes in both length and offset. Canal width and required offset do not move in step, so a small stem may leave the offset too short and a large stem may make it too long.
Will a different head length correct an offset problem?
Only partly. The head sits on the angled neck of the stem, so a longer head adds both length and offset, and an attempt to recover horizontal distance may lengthen the leg as well.
What sets the Exeter Stem apart?